Mostrar el registro sencillo del ítem

dc.contributor.authorBravo Sánchez, Alfredo
dc.contributor.authorAbián, Pablo
dc.contributor.authorLucenteforte, Giacomo
dc.contributor.authorJiménez, Fernando
dc.contributor.authorAbián Vicen, Javier
dc.date.accessioned2022-12-09T11:14:52Z
dc.date.available2022-12-09T11:14:52Z
dc.date.issued2022
dc.identifier.issn1424-8220spa
dc.identifier.urihttps://hdl.handle.net/10641/3178
dc.description.abstractThe aim of the study was to describe the applicability of shear wave elastography to assess muscular and tendinous stiffness of the lower limbs during an incremental isometric strength test and to differentiate the stiffness evolution between superficial and deep muscle regions. Dominant rectus femoris and patellar tendons of 30 physically active people (28.3 9.2 years, 173.2 7.7 cm, 76.2 12.6 kg) were measured in different isometric strength conditions (relaxed muscle, and at 10%, 20%, 30%, 40%, 50% and 60% of maximal voluntary contraction (MVC)). The percentage of success was >85% at all muscle contraction intensities for rectus femoris muscles but only in a relaxed condition for patellar tendons. Rectus femoris stiffness significantly increased compared to the relaxed condition from 30% to 60% MVC (p 0.011) in superficial muscle regions, and from 10% to 60% MVC (p 0.002) in deep muscle regions. Deep muscle regions showed higher stiffness values than superficial muscle regions at 30% MVC (51.46 38.17 vs. 31.83 17.05 kPa; p = 0.019), 40% MVC (75.21 42.27 vs. 51.25 28.90 kPa; p = 0.018), 50% MCV (85.34 45.05 vs. 61.16 37.03 kPa; p = 0.034) and 60% MVC (109.29 40.04 vs. 76.67 36.07 kPa; p = 0.002). Rectus femoris stiffness increased during the incremental isometric contraction test, and inter-region differences were found at 30% MVC.spa
dc.language.isospaspa
dc.publisherSensorsspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectMusclespa
dc.subjectTendonspa
dc.subjectMechanical propertiesspa
dc.subjectUltrasoundspa
dc.titleThe Applicability of Shear Wave Elastography to Assess Myotendinous Stiffness of Lower Limbs during an Incremental Isometric Strength Test.spa
dc.typejournal articlespa
dc.type.hasVersionAMspa
dc.rights.accessRightsopen accessspa
dc.description.extent1854 KBspa
dc.identifier.doi10.3390/s22208033spa
dc.relation.publisherversionhttps://www.mdpi.com/1424-8220/22/20/8033spa


Ficheros en el ítem

FicherosTamañoFormatoVer
1.- The Applicability of Shear ...1.809MbPDFVer/

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 3.0 España