Browsing by Author "Ruiz, Jonatan R."
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item Inter-Day Reliability of Resting Metabolic Rate and Maximal Fat Oxidation during Exercise in Healthy Men Using the Ergostik Gas Analyzer.(Nutrients, 2021) Robles González, Lidia; Gutiérrez Hellín, Jorge; Aguilar Navarro, Millán; Ruiz Moreno, Carlos; Muñoz Moreno, Alejandro; Del Coso, Juan; Ruiz, Jonatan R.; Amaro Gahete, Francisco J.The attainment of high inter-day reliability is crucial to determine changes in resting metabolic rate (RMR), respiratory exchange ratio (RER), maximal fat oxidation during exercise (MFO) and the intensity that elicits MFO (Fatmax) after an intervention. This study aimed to analyze the inter-day reliability of RMR, RER, MFO and Fatmax in healthy adults using the Ergostik gas analyzer. Fourteen healthy men (age: 24.4 ± 5.0 years, maximum oxygen uptake (VO2max): 47.5 ± 11.9 mL/kg/min) participated in a repeated-measures study. The study consisted of two identical experimental trials (Day 1 and Day 2) in which the participants underwent an indirect calorimetry assessment at resting and during an incremental exercise test. Stoichiometric equations were used to calculate energy expenditure and substrate oxidation rates. There were no significant differences when comparing RMR (1999.3 ± 273.9 vs. 1955.7 ± 362.6 kcal/day, p = 0.389), RER (0.87 ± 0.05 vs. 0.89 ± 0.05, p = 0.143), MFO (0.32 ± 0.20 vs. 0.31 ± 0.20 g/min, p = 0.776) and Fatmax (45.0 ± 8.6 vs. 46.4 ± 8.4% VO2max, p = 0.435) values in Day 1 vs. Day 2. The inter-day coefficient of variation for RMR, RER, MFO and Fatmax were 4.85 ± 5.48%, 3.22 ± 3.14%, 7.78 ± 5.51%, and 6.51 ± 8.04%, respectively. In summary, the current results show a good inter-day reliability when RMR, RER, MFO and Fatmax are determined in healthy men using the Ergostik gas analyzer.Item Is there an optimum endurance polygenic profile?(The Journal of Physiology, 2009) Ruiz, Jonatan R.; Gómez-Gallego, Félix; Santiago, Catalina; González-Freire, Marta; Verde, Zoraida; Foster, Carl; Lucia, AlejandroWe analysed seven genetic polymorphisms that are candidates to explain individual variations in human endurance phenotypic traits, at least in Caucasian people (ACE Ins/Del, ACTN3 Arg577Ter, AMPD1 Gln12Ter, CKMM 1170 bp/985 + 185 bp, HFE His63Asp, GDF-8 Lys153Arg and PPARGC1A Gly482Ser) in 46 world-class endurance athletes and 123 controls (all Spanish Caucasians). Using the model developed by Williams & Folland we determined (1) the 'total genotype score' (TGS, from the accumulated combination of the seven polymorphisms, with a maximum value of '100' for the theoretically optimal polygenic score) in the non-athlete (control) group, in the athlete group and in the total Spanish population, and (2) the probability for the occurrence of Spanish individuals with the 'perfect' polygenic endurance profile (i.e. TGS = 100). The probability of a Spanish individual possessing a theoretically optimal polygenic profile for up to the seven candidate genetic polymorphisms we studied was very small, i.e. approximately 0.07% (or 1 in 1351 Spanish individuals). The mean TGS was higher in athletes (70.22 +/- 15.58) than in controls (62.43 +/- 11.45) and also higher than predicted for the total Spanish population (60.80 +/- 12.1), suggesting an overall more 'favourable' polygenic profile in the athlete group. However, only three of the best Spanish endurance athletes (who are also amongst the best in the world) had the best possible score for up to six genes and none of them had the optimal profile. Other polymorphisms yet undiscovered as well as several factors independent of genetic endowment may explain why some individuals reach the upper end of the endurance performance continuum.Item No diurnal variation is present in maximal fat oxidation during exercise in young healthy women.(European Journal of Sport Science, 2023) Robles González, Lidia; Aguilar Navarro, Millán; López Samanés, Álvaro; Ruiz Moreno, Carlos; Muñoz Moreno, Alejandro; Varillas Delgado, David; Gutiérrez Hellín, Jorge; Helge, Jørn W.; Ruiz, Jonatan R.; Amaro-Gahete, Francisco J.Maximal fat oxidation during exercise (MFO) and the intensity that elicits MFO (Fatmax) seems to show a diurnal variation in men, which favours an increased performance in the afternoon than the morning. At present, it remains unknown whether the observed MFO and Fatmax diurnal variation in men is also present in women. Therefore, the current study examined the diurnal variations of MFO and Fatmax in women. Nineteen healthy women (age: 26.9 ± 8.7 years, maximum oxygen uptake: 39.8 ± 6.5 ml/kg/min) participated in the study. MFO and Fatmax were determined by a graded exercise test in cycloergometer using a cross-over design performed on two separate daytime schedules, one conducted in the morning (8am–11am) and one in the afternoon (5pm–8pm). Stoichiometric equations were used to calculate fat oxidation rates. There were no significant differences between MFO-morning and MFO-afternoon (0.24 ± 0.10 vs. 0.23 ± 0.07 g/min, respectively; P = 0.681). Similarly, there was no significant differences between Fatmax-morning and Fatmax-afternoon (41.1 ± 4.7 vs. 42.6 ± 5.5% of maximal oxygen uptake, respectively; P = 0.305). These results persisted after controlling for fat mass percentage (all P > 0.5). In summary, the main finding of the present study was that MFO and Fatmax were similar independent of the time-of-day when the exercise test is performed in healthy women. These results have important clinical implications since they suggest that, in contrast to what was found in men, MFO and Fatmax show similar rates during the course of the day in women.