Miralles-Iborra, AaronUrban, TomasDe Los Ríos-Calonge, JavierElvira, Jose L.L.Del Coso, JuanTomás-Rodríguez, María IsabelJuan-Recio, CastoMoreno-Pérez, Víctor2026-09-302026-09-302026-04Miralles-Iborra, A, Urban, T, De Los Ríos-Calonge, J, Elvira, J L L, Del Coso, J, Tomás-Rodríguez, M I, Juan-Recio, C & Moreno-Pérez, V 2026, 'Dynamic Field Assessment of Hip Adductor Function Using a Smartphone-Based Copenhagen Test : Reliability and Concurrent Associations with Isometric Strength in Amateur Football Players', Sports, vol. 14, no. 4, 125. https://doi.org/10.3390/sports140401252075-4663PubMedCentral: PMC13120274https://hdl.handle.net/10641/8370Publisher Copyright: © 2026 by the authors.Evaluar la fuerza del músculo aductor de la cadera es importante para identificar debilidad o desequilibrios entre lados asociados con el riesgo de lesión inguinal. Aunque el ejercicio del aductor de Copenhague se utiliza ampliamente para evaluar la función del aductor, la cuantificación de los resultados relacionados con la fuerza mediante sensores inerciales integrados en smartphones durante esta tarea no se ha examinado sistemáticamente. Este estudio tuvo como objetivo evaluar la fiabilidad de una prueba de campo del aductor de Copenhague basada en smartphone y sus asociaciones con las evaluaciones establecidas de fuerza isométrica del aductor de cadera. Veinte futbolistas amateurs varones (21,1 ± 3,2 años) completaron dos sesiones de laboratorio separadas por una semana. Se evaluó la fiabilidad de la prueba de Copenhague basada en smartphone para el resultado relacionado con la resistencia (número de repeticiones) y los resultados relacionados con la fuerza (tiempo medio de repetición y velocidad pico) mediante coeficientes de correlación intraclase (CCI), error estándar de medición (SEM) y cambio mínimo detectable (MDC). Los participantes también realizaron pruebas isométricas unilaterales y bilaterales del aductor de cadera utilizando celdas de carga para obtener la fuerza pico isométrica (IPF) y la tasa de desarrollo de fuerza a 150 ms (RFD150). Las asociaciones se examinaron mediante coeficientes de correlación de Pearson. La prueba de Copenhague basada en smartphone mostró estimaciones puntuales de CCI que oscilaron entre 0,63 y 0,83, aunque varios intervalos de confianza del 95% fueron relativamente amplios (CCI = 0,63–0,83; SEM = 6,7–18,5%). Los resultados relacionados con la resistencia no se asociaron significativamente con IPF ni con RFD150. Por el contrario, la velocidad pico mostró correlaciones bajas a moderadas con RFD150 (r = 0,48–0,63) y correlaciones moderadas con IPF (r = 0,50–0,64; p < 0,05). Estos hallazgos sugieren que la velocidad pico obtenida durante la prueba del aductor de Copenhague puede proporcionar un complemento práctico de campo a las evaluaciones isométricas convencionales. Sin embargo, dada la fuerza moderada de las asociaciones observadas y el error de medición de la velocidad pico, estos resultados deben interpretarse con cautela y requieren mayor investigación. [Traducción automática al español; idioma original: inglés.]Assessing hip adductor muscle strength is important for identifying weakness or side-to-side imbalances associated with groin injury risk. Although the Copenhagen adductor exercise is widely used to evaluate adductor function, the quantification of strength-related outcomes using inertial sensors integrated in smartphones during this task has not been systematically examined. This study aimed to evaluate the reliability of a smartphone-based Copenhagen adductor field test and its associations with established isometric hip adductor strength assessments. Twenty amateur male football players (21.1 ± 3.2 years) completed two laboratory sessions separated by one week. The reliability of the smartphone-based Copenhagen test was assessed for endurance-related outcome (repetition count) and strength-related outcomes (mean repetition time and peak velocity) using intraclass correlation coefficients (ICC), standard error of measurement (SEM), and minimum detectable change (MDC). Participants also performed unilateral and bilateral isometric hip adductor tests using load cells to obtain isometric peak force (IPF) and rate of force development at 150 ms (RFD150). Associations were examined using Pearson correlation coefficients. The smartphone-based Copenhagen test showed ICC point estimates ranging from 0.63 to 0.83, although several 95% confidence intervals were relatively wide (ICC = 0.63–0.83; SEM = 6.7–18.5%). Endurance-related outcomes were not significantly associated with IPF or RFD150. In contrast, peak velocity showed low-to-moderate correlations with RFD150 (r = 0.48–0.63) and moderate correlations with IPF (r = 0.50–0.64; p < 0.05). These findings suggest that the peak velocity obtained during the Copenhagen adductor test may provide a practical field-based complement to conventional isometric assessments. However, given the moderate strength of the observed associations and the measurement error of peak velocity, these outcomes should be interpreted with caution and warrant further investigation.14792800enghttp://creativecommons.org/licenses/by-nc-nd/4.0/consistencyfield-based testinggroin injuryhip adduction torquerate of force developmentwearable sensorsOrthopedics and Sports MedicinePhysical Therapy, Sports Therapy and RehabilitationJournal ArticleYesDynamic Field Assessment of Hip Adductor Function Using a Smartphone-Based Copenhagen Test : Reliability and Concurrent Associations with Isometric Strength in Amateur Football PlayersEvaluación dinámica de campo de la función del aductor de cadera mediante una prueba de Copenhague basada en smartphoneFiabilidad y asociaciones concurrentes con la fuerza isométrica en futbolistas amateursjournal articleopen access10.3390/sports14040125https://www.scopus.com/pages/publications/105036827398https://www.scopus.com/pages/publications/105036827398#tab=citedBy