Influence of donor capnometry on renal graft evolution in uncontrolled donation after circulatory death.

dc.contributor.authorRubio Chacón, Carlos
dc.contributor.authorMateos Rodríguez, Alonso
dc.contributor.authorNeria Serrano, Fernando
dc.contributor.authorDel Río Gallegos, Francisco
dc.contributor.authorAndrés Belmonte, Amado
dc.date.accessioned2024-02-28T19:20:37Z
dc.date.available2024-02-28T19:20:37Z
dc.date.issued2023
dc.description.abstractAim To analyse the association between donor capnometry data and the short-term evolution of kidney grafts in cases of uncontrolled donation after circulatory death (uDCD). Method We used an ambispective observational study design, conducted in the Community of Madrid between January and December 2019, inclusive. Patients who suffered out-of-hospital cardiac arrest (CA) with no response to advanced cardiopulmonary resuscitation (CPR) were selected as potential donors. Donor capnometry levels were measured at the start, midpoint and transfer to hospital then compared with indicators of renal graft evolution. Results The initial selection included 34 possible donors, of which 12 (35.2%) were viable donors from whom 22 (32.3%) kidneys were recovered. There was a correlation between the highest capnometry values and less need for post-transplant dialysis (≥24 mmHg, p < 0.017), fewer dialysis sessions and fewer days to recover correct renal function (Rho −0.47, p < 0.044). There was a significant inverse correlation between the capnometry values at transfer and 1-month post-transplant creatinine levels (Rho −0.62, p < 0.033). There were no significant differences between the capnometry values at transfer and primary nonfunction (PNF) or warm ischaemia time. One-year patient survival was 100% for patient receiving organ donation, while graft survival was 95%. Conclusions Capnometry levels at transfer are a useful predictor of the short-term function and viability of kidney transplants from uncontrolled donations after circulatory death.spa
dc.description.extent713 KBspa
dc.identifier.doi10.1016/j.resuscitation.2023.109863spa
dc.identifier.issn0300-9572spa
dc.identifier.urihttps://hdl.handle.net/10641/4170
dc.language.isoengspa
dc.publisherResuscitationspa
dc.relation.publisherversionhttps://www.resuscitationjournal.com/article/S0300-9572(23)00176-4/fulltextspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectCapnometryspa
dc.subjectKidney transplantspa
dc.subjectAsystolespa
dc.subjectResuscitationspa
dc.subjectEmergency medical servicesspa
dc.titleInfluence of donor capnometry on renal graft evolution in uncontrolled donation after circulatory death.spa
dc.typejournal articlespa
dc.type.hasVersionAMspa
dspace.entity.typePublication
relation.isAuthorOfPublication164b6d6e-2093-48d5-bf85-49adbc81ca10
relation.isAuthorOfPublication.latestForDiscovery164b6d6e-2093-48d5-bf85-49adbc81ca10

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PIIS0300957223001764.pdf
Size:
712.4 KB
Format:
Adobe Portable Document Format
Description:

Collections